| Specifications: |
| Capacity: |
0.1 Liter |
| Type of system (max. static pressure): |
non-pressure with special open-outlet tap, 10 bar/145 psi |
| Heating System: |
bare heating element |
| Minimum required specific water resistance: |
greater than or equal to 1,100 ohm cm at 15°C |
| Nominal rating/-loading at 1/N/PE ~ 220V: |
3.2 kW/14.5 A |
| Nominal rating/-loading at 1/N/PE ~ 230V: |
3.5 kW/15.2 A |
| Nominal rating/-loading at 1/N/PE ~ 240V: |
3.8 kW/15.8 A |
| Required cable minimum: |
3 x 1.5 mm² |
| Switch-on flow pressure: |
1.2 bar/17.4 psi |
| Maximum temp rise @ flow limited to: |
25 K @ 2 l/min |
| Flow with temp rise of t=20K i.e, from 20°C to 40°C (mixed with cold water) |
2.5 l/min |
| Maximum remp rise @ flow: |
40K @ 1.3 l/min |
| Suitable for areas with cold water temps of: |
15 - 25°C |
| Water connection: |
G 1/2" wall connection |
| Weight: |
2 kg |
| Dimensions (H x W x D): |
31 x 19 x 9 cm |
| Class / Degree of protection (IEC 529): |
1 / IP 25 |